Switch to English①散熱器的散熱是以瓦作為熱功率計量(W)指每組(柱)散熱器在不同工況下每小時的散熱量
衛浴暖氣:Q=2.505△T1.348 (1200*600)
標準工況: △T=64.5℃(即進水溫度95℃,出水溫度70 ℃,室溫18℃)
②華北地區節能墻體每平方米
集中供暖90W左右配置
獨立供暖110W左右配置
房間東南向可少10%,西北向多出10%。
樓層:目前的供暖技術,對樓層沒有太多的區別,但舊樓房,頂樓可適當增加10%余量。
③若安裝溫控閥,必須過熱才可調控。散熱量小了,溫控閥是不起作用的,它不可能把溫度調高。
① heat sink heat sink is the tile as the thermal power measurement (W) Refers to each group (column) Radiator in different conditions, the heat per hour
Bathroom heating: Q = 2.505 △ T1.348 (1200 * 600)
Standard conditions: △ T = 64.5 ℃ (that is, inlet temperature 95 ℃, water temperature 70 ℃, room temperature 18 ℃)
② North China energy-saving wall per square meter
Central heating about 90W configuration
Independent heating about 110W configuration
Room southeast to 10% less, to the northwest to 10% more.
Floor: the current heating technology, the floor is not much difference, but the old buildings, the top floor may be an appropriate increase of 10% margin.
③ If you install the thermostatic valve, you must overheat to control. The heat is small, the thermostatic valve does not work, it is impossible to increase the temperature.